Tank installation and CIP

4Connections4Seats and 4Connections3Seats BD (Barrier&Drain) Robolux valves installed for tank service

 Robolux valve solution   Conventional valve solution
   
Saving and benefits in this example are:  
  • Valves reduced from 7 to 2
  • Tee's reduced from 2 to 0 and crosse's from 1 to 0
  • Diaphragms reduced from 7 to 4 
  • Elimination of 8 welds
   

Shown are a 4Connections4Seats and a 4Connections3Seats BD (Barrier & Drain) valve.

 
  • Dead Legs Eliminated
  • Crosscontamination Reduced
  • Improved Flow Shift Characteristics
  • Minimized production losses and waste
 
  • Minimum Space Requirements
  • Reduced Installation Costs
  • Minimized Maintenance Cost
  • Increased production efficiency 